LOCTITE IS 5110

Harmonization Code : 2901.10.00.00 | Acyclic hydrocarbons; Saturated

LOCTITE IS5110

Main features

  • Low-Viscosity Leak-Path Impregnation
  • Water-Rinsable Post-Impregnation Cleanup
  • Anaerobic Sealing Inside Porosity

Product Description

LOCTITE IS 5110 is a one-component, low-viscosity anaerobic sealant for vacuum impregnation of interfacial leak paths in rigid electronic assemblies. Its typical viscosity is 36 to 66 mPa s at 25 deg C, allowing liquid sealant to saturate internal porosity during vacuum impregnation. Excess material disperses in water and is rinsed from exterior surfaces before the retained sealant cures in the absence of freely available oxygen. The cured thermoset has Shore D 89 hardness, volume resistivity of 9 x 10^13 ohm cm, and a continuous-temperature design limit of 205 deg C. Applications include overmolded components, connectors, coils, lamination stacks, solenoids, and sealed enclosures.

Key features

  • Low-Viscosity Vacuum Impregnation: Typical viscosity is 36 to 66 mPa s at 25 deg C for the vacuum-impregnation process.
  • Water-Dispersible Excess Sealant: Excess liquid disperses in water for post-impregnation rinsing from exterior surfaces.
  • Anaerobic Internal Cure: Sealant retained inside porosity polymerizes where freely available oxygen is absent.

Applications

Vacuum impregnation and leak-path sealing in overmolded electrical components, connectors, high-temperature coils, lamination stacks, solenoids, and sealed enclosures.

Technical Specifications

General Properties
Appearance
Transparent liquid
Chemistry Type
Methacrylate monomers
Density (g)
1.21 g/cm3
Specific Gravity
1.09
Physical Properties
Viscosity
36 to 66 mPa.s
Electrical Properties
Volume Resistivity
9×10¹³ Ohms⋅cm
Other Properties
Storage Temperature
8 °C to 21 °C

Additional Information

Technical properties

As-supplied / before-processing properties

PropertyValueUnitMethod / condition
Specific gravity1.09-Typical; 25 deg C
Surface tension42.3dynes/cmTypical; ASTM D1590
Viscosity36 to 66mPa sLMS range; Brookfield RVT, 25 deg C, spindle 2, 50 rpm
Technical properties

After-processing / final-state properties

PropertyValueUnitMethod / condition
Shore hardness89Durometer DTypical; ISO 868
Continuous-temperature design limit205deg CDesign limit; continuous temperature
Compressive modulus1,790N/mm^2Typical; ISO 604
Flexural modulus1,740N/mm^2Typical; ASTM D790
Volume resistivity9 x 10^13ohm cmTypical; IEC 60093
Dielectric breakdown strength39.4kV/mmTypical; IEC 60243-1

Leading Brands Trust in Our Products and Services

Products that Perform| Knowledge that Serves| Service that Delivers