ECCOBOND 3730

Harmonization Code : 3919.10.80 | Other self-adhesive plastic rolls not exceeding 20 cm wide.

ECCOBOND 3730

Main features

  • Tack-Free in 15 Seconds or Less
  • At Least 2.5 mm Cure Depth
  • 17 kV/mm Dielectric Strength

Product Description

LOCTITE 3730 is a one-part, transparent amber acrylic sealant for UV/visible-light curing in LCD end-sealing. Typical viscosity is 22,000 to 28,000 mPa s at 25 deg C under the stated Haake test. At 40 mW/cm^2 measured at 365 nm, tack-free time is 15 seconds or less, while a 50-second exposure provides a listed UV cure depth of at least 2.5 mm. After cure, typical properties include Shore D 82 hardness, 17 kV/mm dielectric breakdown strength, and 7.0E+12 ohm*cm volume resistivity. The material is used as an electrically insulating end seal for LCD assemblies.

Key features

  • 15-Second-or-Less Tack-Free Time: Measured at 40 mW/cm^2 and 365 nm with a high-pressure mercury arc source.
  • At Least 2.5 mm UV Cure Depth: Measured after 50 seconds at 40 mW/cm^2 and 365 nm.
  • 17 kV/mm Dielectric Breakdown Strength: Typical cured value is measured to IEC 60243-1.
Product Family

ECCOBOND 3730

Loading pricing…

TDS, SDS & Technical Documents

Technical Specifications

General Properties
Appearance
Appearance at room temperature.
Transparent amber liquid
Chemistry Type
Acrylate
Physical Properties
Viscosity
Viscosity is a measurement of a fluid’s resistance to flow. Viscosity is commonly measured in centiPoise (cP). One cP is defined as the viscosity of water and all other viscosities are derived from this base. MPa is another common unit with a 1:1 conversion to cP. A product like honey would have a much higher viscosity -around 10,000 cPs- compared to water. As a result, honey would flow much slower out of a tipped glass than water would. The viscosity of a material can be decreased with an increase in temperature in order to better suit an application
22,000 to 28,000 mPa.s
Electrical Properties
Dielectric Strength
Dielectric strength is measured in kV per mm and is calculated by the Breakdown voltage divided by the thickness of the tested material. Those two properties go hand in hand and while Breakdown voltage is always thickness dependent, dielectric strength is a general material property. As an example, the dielectric strength of Polyimide is 236 kV/mm. If we place 1mm of Polyimide between two electrodes, it will act as an insulator until the voltage between the electrodes reaches 236 kV. At this point it will start acting as a good conductor, causing sparks, potential punctures and current flow.
17 kV/mm
Volume Resistivity
Volume resistivity, also called volume resistance, bulk resistance or bulk resistivity is a thickness dependent measurement of the resistivity of a material perpendicular to the plane of the surface.
7.0×10¹² Ohms⋅cm

Additional Information

Technical properties

As-supplied / before-processing properties

PropertyValueUnitMethod / condition
Viscosity22,000 to 28,000mPa s25 deg C; Haake PK1, 20 s^-1; LMS
Tack-free time<=15s40 mW/cm^2 at 365 nm; high-pressure mercury arc; LMS
UV cure depth>=2.5mm40 mW/cm^2 at 365 nm for 50 s; LMS
Technical properties

After-processing / final-state properties

PropertyValueUnitMethod / condition
CTE at -30 deg C55E-61/KISO 11359-2; typical
CTE at 30 deg C140E-61/KISO 11359-2; typical
CTE from 50 to 150 deg C190E-61/KISO 11359-2; typical
Shore hardness82Shore DISO 868; typical
Surface resistivity4.0E+15ohmIEC 60093; typical
Volume resistivity7.0E+12ohm*cmIEC 60093; typical
Dielectric breakdown strength17kV/mmIEC 60243-1; typical